CHC Plus
Pre-compliant 3m Compact EMC Chamber
Overview
EMI
EMS
Test distance
Volume
Special
CISPR 16-1-4
IEC/EN 61000-4-3
3,0m
ø1,2 m
Pre-compliant EMI from 30 MHz to 1 GHz
Full compliant EMI from 1 GHz to 18 GHz
Full compliant EMS
The CHC Plus is Frankonia’s version of the compact hybrid chamber solution at 3,0m measuring distance with a Quiet Zone (QZ) of ø1,2m that meets the SVSWR verification. The CHC Plus is an upgradable solution and can transform from a semi anechoic chamber configuration with ground plane to a fully anechoic chamber configuration with floor absorbers. It is an optimal solution for both pre-compliance emission tests and full compliance immunity tests at 3,0m measuring distance.
Features
> Full compliant EMS and pre-compliant EMI solution up to 1 GHz (NSA), full compliant above 1 GHz (SVSWR)
> Cost effective solution for EMS and limited EMI measurements
> Compact chamber design with advanced absorber lining with long-lasting Frankosorb® absorbers
(Frankonia technology)
> Turnkey solution
Typical Product Standards
Emission
> Pre-compliant from
30 MHz to 1 GHz
> Full compliant from
1 GHz to 18 GHz
Immunity
> IEC/EN 61000-4-3
Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.
Typical Verification Standards
Emission
> CISPR 16-1-4
Immunity
> IEC/EN 61000-4-3
Technical specifications
Chamber
External dimension
Quiet Zone
Measuring distance
Turntable
Frequency range
CHC Plus
7.355 x 3.755 x 3.300 mm
ø1,2 m; height 2,0 m
3,0 m
ø1,2 m
​
30 MHz to 18 GHz (option 40 GHz)
CHC Plus L
7.580 x 4.655 x 4.350 mm
​
​
​
​
​
ø2,0 m
Performance & Compliance
> Pre-compliant emission (EMI) according to CISPR 16-1-4 from 30 MHz- 1 GHz
> Full compliant emission (EMI) according to CISPR 16-1-4 from 1 GHz- 18 GHz
> Full compliant immunity (EMS) according to IEC/EN 61000-4-3