top of page
CHC Plus

Pre-compliant 3m Compact EMC Chamber

Overview

EMI

 

EMS

 

Test distance

 

Volume

 

Special

CISPR 16-1-4

 

IEC/EN 61000-4-3

 

3,0m

 

ø1,2 m

 

Pre-compliant EMI from 30 MHz to 1 GHz
Full compliant EMI from 1 GHz to 18 GHz
Full compliant EMS

CHC Plus 1.png

The CHC Plus is Frankonia’s version of the compact hybrid chamber solution at 3,0m measuring distance with a Quiet Zone (QZ) of ø1,2m that meets the SVSWR verification. The CHC Plus is an upgradable solution and can transform from a semi anechoic chamber configuration with ground plane to a fully anechoic chamber configuration with floor absorbers. It is an optimal solution for both pre-compliance emission tests and full compliance immunity tests at 3,0m measuring distance.

CHC Plus 3.png
CHC Plus 2.png

Features

>     Full compliant EMS and pre-compliant EMI solution up to 1 GHz (NSA), full compliant above 1 GHz (SVSWR)

>     Cost effective solution for EMS and limited EMI measurements

>     Compact chamber design with advanced absorber lining with long-lasting Frankosorb® absorbers

        (Frankonia technology)

>     Turnkey solution

Typical Product Standards

Emission

>     Pre-compliant from  

        30 MHz to 1 GHz

>     Full compliant from

        1 GHz to 18 GHz

Immunity

>     IEC/EN 61000-4-3

Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.

Typical Verification Standards

Emission

>     CISPR 16-1-4

Immunity

>     IEC/EN 61000-4-3

Technical specifications

Chamber

 

External dimension

 

Quiet Zone

 

Measuring distance

 

Turntable

 

Frequency range

CHC Plus

 

7.355 x 3.755 x 3.300 mm

 

ø1,2 m; height 2,0 m

 

3,0 m

 

ø1,2 m

​

30 MHz to 18 GHz (option 40 GHz)

CHC Plus L

 

7.580 x 4.655 x 4.350 mm

​

​

​

​

​

ø2,0 m

Performance & Compliance

>     Pre-compliant emission (EMI) according to CISPR 16-1-4 from 30 MHz- 1 GHz

>     Full compliant emission (EMI) according to CISPR 16-1-4 from 1 GHz- 18 GHz

>     Full compliant immunity (EMS) according to IEC/EN 61000-4-3

bottom of page