CIP 9136
The CIP 9136 probe has been manufactured to drawings and specifications laid down by QinetiQ.

 

PCJ 9201
The PCJ 9201 meets all the requirements and provides additionally a save way for measuring the insertion loss of current sensing probes and monitoring probes. 

CIP 9136

Current Injection Probe 10 kHz - 400 MHz

  • Wide frequency range 10 kHz - 400 MHz

  • High power handling (up to 1 kW)

  • Ideal for automotive BCI testing e.g. ISO 11452-4, RTCA/DO-160 section 20, MIL-STD-461 and manufacture‘s requirements

  • Meets IEC/EN 61000-4-6

  • Replacement for CIP 36A & 37A as specified in Defence Standard 59-41

Description

The CIP 9136 probe has been manufactured to drawings and specifications laid down by QinetiQ. It meets the requirements for HIRF testing where conventional ferrite core material cannot handle the higher powers required (up to 1000 W), without changing characteristics when heated. Whilst having been initially designed to meet the specific requirements of Aircraft Testing from 10 kHz to 50 MHz, the CIP 9136’s unique non-ferrite core allows wide band performance from 10 kHz - 400 MHz, and above.

 

The CIP 9136 core material is highly efficient and thermally rugged, thus allowing very high injected levels to be achieved with lower RF input powers. The core material can withstand far higher powers than conventional ferrite (up to 1000 W), which change characteristics in relation to the temperature.

PCJ 9201

Calibration Jig for Current Probes

  • Calibration jig for current probes

  • Meets ISO 11452-4, RTCA/DO-160 section 20, MIL-STD-461 and IEC/EN 61000-4-6

  • Ruggedly designed

  • Enhanced VSWR up to 400 MHz

Description

The standards RTCA/DO-160 section 20 (Environmental Conditions and Test Procedures for Airborne Equipment Section 20: Radio Frequency Susceptibility (Radiated and Conducted)), MIL-STD-461 (REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT) and IEC/EN 61000-4-6 (Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields) define a method for test level setting in a calibration jig. The PCJ 9201 meets all the requirements and provides additionally a save way for measuring the insertion loss of current sensing probes and monitoring probes. The enhanced VSWR offers measurements in range up to 400 MHz.

Product Suggestions
Screen Shot 2556-06-02 at 8.34.00 PM.png

I/O Interface

IOB 4000
The Input/Output Box, in short IOB 4000, is an ideal addition for electromagnetic immunity test systems.

 

USO 4013
The USO 4013 is a fast, universal USB-to-serial converter with an optical and an RS232 port, which can be optionally configured as an RS485 port.

Screen Shot 2556-06-02 at 8.41.30 PM.png

Line Impedance Stabilization Networks (LISN)

Line Impedance Stabilization Network (LISN) such as the NNB 51 and NNB 52 are used to measure distortion signals on the power cord of an electrical Equipment Under Test (EUT).

Screen Shot 2556-06-02 at 8.47.21 PM.png

NSG 3040-DDV

Single function generator for single phase Dips Interrupts & Variations testing up to 270 V/16 A in compliance with IEC61000-4-11 and IEC61000-4-29

  • Fully IEC 61000-4-11 & 29 compliant

  • Large color display and touch panel interface

  • Standards and user test libraries

  • Wide range of accessories