ESD Simulators

Electrostatic Discharge (ESD) tests are used to verify complete systems and duplicate disturbances in installations. These tests contribute to identify immunity failures caused by bad cabling or system composition, as well as grounding problems.
Teseq’s ESD simulators fulfill the requirements of all major ESD standards. Thanks to stabilized HV output all Teseq simulators exceed this need by far and guarantee optimized reproducibility of tests. The basic models are type-approved and calibrated to IEC/EN 61000-4-2. A comprehensive range of additional network modules are available for testing to various standards including ISO 10605.

 

For information on our large accessory range (discharge networks, special discharge tips, calibration and test setup accessories) please contact your local Teseq supplier.

Product  Description

  • NSG 434 ESD SIMULATOR

       Electrostatic Discharge (ESD) simulator for immunity testing in compliance with IEC 61000-4-2, up to 8.8 kV

 

  • NSG 435 ESD SIMULATOR

       Electrostatic Discharge (ESD) simulator for immunity testing in compliance with IEC 61000-4-2, up to 16.5 kV

 

  • NSG 437 ESD SIMULATOR

       Electrostatic Discharge (ESD) simulator for immunity testing in compliance with IEC61000-4-2 and ISO10605,

       up to 30 kV.

  • NSG 438 HIGH END ESD SIMULATOR

       Electrostatic Discharge (ESD) simulator for immunity testing in compliance with IEC61000-4-2 and ISO10605,

       up to 30 kV.

 

  • NSG 439 ESD SIMULATOR

       Electrostatic Discharge (ESD) simulator for immunity testing in compliance with IEC 61000-4-2 and ISO 10605,

       up to 30 kV. Designed especially for robotic applications.  

NSG 434 ESD SIMULATOR

Electrostatic Discharge (ESD) simulator for immunity testing in compliance with IEC 61000-4-2, up to 8.8 kV

Basic Performance in a Compact Design

  • Programmable discharge voltage 200 V to 8.8 kV

  • Stabilized charging voltage

  • Pre-programmed IEC/EN 61000-4-2 test settings up to level 3

  • True air-discharge breakdown voltage

  • Battery powered

Description

Ergonomic design and advanced functionality. The pistol-shaped NSG 434 simulator is designed to sit comfortably in the operator’s hand, with current operating conditions constantly displayed and clearly visible.

NSG 434’s microprocessor-based controller and multifunction keypad provide the operator with instant access to its comprehensive range of built-in functions. The LCD panel continuously displays the operating status and all user-selected test parameters.

NSG 434 has its own internal, battery operated high voltage generator. In addition to the pre-programmed, standard IEC pulses, the user can create custom tests using single or repetitive discharges with selectable rates and manual or automatic polarity switching. An optional mains supply is available for extended test operation or for use when the battery is being charged.

NSG 435 ESD SIMULATOR

Electrostatic Discharge (ESD) simulator for immunity testing in compliance with IEC 61000-4-2, up to 16.5 kV

Compact and Cost Effective

  • Programmable discharge voltage 200 V to 16.5 kV

  • Stabilized charging voltage

  • Pre-programmed IEC/EN 61000-4-2 test settings

  • True air-discharge breakdown voltage

  • Compact and lightweight design

Description

Ergonomic design and advanced functionality. The pistol-shaped NSG 435 simulator is designed to sit comfortably in the operator’s hand, with current operating conditions constantly displayed and clearly visible.

NSG 435’s microprocessor-based controller and multifunction keypad provide the operator with instant access to its comprehensive range of built-in functions. The LCD panel continuously displays the operating status and all user-selected test parameters.

NSG 435 has its own internal, battery operated high voltage generator. In addition to the pre-programmed, standard IEC pulses, the user can create custom tests using single or repetitive discharges with selectable rates and manual or automatic polarity switching. An optional mains supply is available for extended test operation or for use when the battery is being charged.

NSG 437 ESD SIMULATOR

Electrostatic Discharge (ESD) simulator for immunity testing in compliance with IEC61000-4-2 and ISO10605, up to 30 kV.

NSG 437 ESD SIMULATOR, High Performance with Basic Features

  • Air- and contact-discharge up to 30 kV

  • Light version featuring uncompromised test performance

  • Compliant with a wide range of standards (IEC, ANSI, SAE, ISO)

  • Touch panel display controls

  • Easily and quickly interchangeable network modules

Description

The NSG 437 simulator is designed to sit comfortably in the operator’s hand, with current operating conditions constantly displayed and clearly visible. The simulator is ergonomically designed to be held easily for long duration test procedures.

The touch panel display with its keypad for parameter settings shows the precise functional and test data at any moment. All essential functions and actual status are displayed, with user-selectable language for convenient and safe operation worldwide.

Pre-programmed settings for IEC/EN 61000-4-2 and ISO 10605 ensure that the simulator is automatically set up correctly. The menu with last settings automatically comes up again after shut-down of a test sequence.

Thanks to stabilized HV output the NSG 437 ESD simulator comprehensively fulfills virtually all international standard requirements. Based on over 20 optional discharge networks, the NSG 437 can also meet any of today’s automotive manufacturers’ standards.

NSG 438 HIGH END ESD SIMULATOR

Electrostatic Discharge (ESD) simulator for immunity testing in compliance with IEC61000-4-2 and ISO10605, up to 30 kV.

Optimized for Automotive Testing

  • Air- and contact-discharge up to 30 kV

  • Compliant with a wide range of standards (IEC, ANSI, SAE, ISO)

  • Built-in ISO self-calibration procedure

  • Powered by high-energy battery pack

  • Touch panel display controls

Description

Ergonomic design and advanced functionality. The pistol-shaped NSG 438 simulator is designed to sit comfortably in the operator’s hand, with current operating conditions constantly displayed and clearly visible.

NSG 438 ESD simulator comprehensively fulfills virtually all international standard requirements and supports proposed future standards. Based on over 20 optional discharge networks, the NSG 438 can also meet any of today’s automotive manufacturers’standards.

The simulator is simple, convenient and safe to use. The whole range of parameter setting possibilities, including polarity selection, freely adjustable pulse repetition, counter functions and breakdown detection, remains fully available up to the maximum discharge voltage.

NSG 439 ESD SIMULATOR

Electrostatic Discharge (ESD) simulator for immunity testing in compliance with IEC 61000-4-2 and ISO 10605, up to 30 kV. Designed especially for robotic applications.

Fully Automated Robotic ESD Testing

  • Complete solution for robotic applications

  • Compact and specially designed housing

  • Unique robotic air-discharge adapter

  • Fully compliant with IEC/EN 61000-4-2 and ISO 10605

Description

Complete system solution with 30 kV ESD simulator for robotic applications.

Today’s growing trend towards miniaturizing and more comprehensive product standards means that ESD testing is now required not only for operating controls, but also for any associated peripheral devices such as sensors, actuators and controllers. Many of these devices have multi-pin connectors with high pin counts. In order to meet space restrictions, these pins are often arranged close together.

However, conventional air-discharge testing of these closely spaced pins is problematic because the airdischarge arc may jump to an adjacent pin instead of the pin intended for test. With an innovative robotic air-discharge adapter accessory, Teseq provides a tool which will prevent unintentional discharge paths. Furthermore, the approach speed, which is crucial for reliable air-discharge testing, can be programmed as a constant.

ESD testing of connectors often requires that each individual pin is tested for an extensive range of conditions including multiple discharges, polarities, voltage settings, and even R/C networks. Connector testing can take many hours or even days of monotonous, precise effort to complete. As a result, when this testing is done manually it is prone to errors. The advantage of robotic testing is that these procedures can be automated and precisely executed, ensuring a level of repeatability that cannot be achieved with manual testing.

Product Suggestions
Screen Shot 2556-06-03 at 12.21.15 AM.pn

Strip Lines

Strip Lines are made for the generation of homogeneous electromagnetic fields and specified in ISO 11452-5 and EU guidelines 95/94. The strip lines can be used for testing of electrical/electronic submodules (EUB) and their associated cables.

Screen Shot 2556-06-02 at 3.20.18 PM.png

AMZ 41

Absorbing Clamp

  • As specified in CISPR 16-1-3

  • Disturbance power measuring, according to CISPR 16-2-2

  • Can be used as diagnostic tool

  • Measurement of screening attenuation of coaxial cables

Screen Shot 2556-06-02 at 3.26.25 PM.png

CMAD 10

Common Mode Absorption Device

  • Frequency range 1 MHz to 1 GHz

  • Max. cable diameter 10 mm

  • Cable termination for radiated emission and immunity tests

  • Ideal for testing in GTEM cells

Address

PNK Engineering and Consultant Co., Ltd. 
222 UPA Place Building B  1st Floor
Soi Ramkumhange 164 Minburee 
Bangkok 10510

Contact

Tel +669 4412 5588   +66 2 170 9244
Fax +66 2 170 9245 

©2018 by PNK Engineering & Consultant create by Big Bear