FAC-3
Fully Anechoic 3m EMC Chamber
Overview
CISPR 16-1-4, IEC/EN 61000-4-22
IEC/EN 61000-4-3
3,0m
ø1,5 m at 1,5m height
Table top EUT’s
EMI
EMS
Test distance
Volume
Special
The FAC-3 is Frankonia’s fully anechoic chamber solution at 3,0m measuring distance for EMC tests on table top positioned EUT’s. It is designed as full compliant chamber for measurements under free-space conditions and is based on CISPR 16-1-4 as a test site without ground plane. Without the reflections from the floor, a height scan is no longer necessary. With its specific requirements for the test site, Frankonia’s FAC-3 is supremely prepared to meet our customers’ demands.
Features
> Test site for table top EUT’s
> Full compliant EMI/EMS
> Cost effective solution for free-space measurements
> Compact chamber design with advanced absorber lining with long-lasting Frankosorb® absorbers (Frankonia
technology)
> Turnkey solution
Typical Product Standards
Emission
> CISPR 14
> CISPR 32
> ETSI
Immunity
> IEC/EN 61000-4-3
Typical Verification Standards
Emission
> CISPR 16-1-4
> IEC/EN 61000-4-22
Immunity
> IEC/EN 61000-4-3
> IEC/EN 61000-4-22
Technical specifications
Chamber
External dimension
EUT
Quiet Zone CISPR 16-1-4
Quiet Zone IEC/EN 61000-4-22
Measuring distance
Load capacity
Frequency range
FAC-3
8.705 x 4.655 x 3.750 mm
Table-top EUT’s
ø1,5 m; height 1,5 m
ø1,5 m; height 1,5 m (30 MHz -1 GHz)
ø1,0 m; height 1,0 m (1 GHz -6 GHz)
3,0m
up to 2,0 tons; special turntable systems possible
30 MHz to 18 GHz (option 40 GHz)
Performance & Compliance
> Full compliant emission (EMI) according to CISPR 16-1-4
Deviation FS NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation FS SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed
> Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed
> Full compliant immunity (EMS) and emission (EMI) according to IEC/EN 61000-4-22 Standard
Deviation SdB c ≤ 1,8 dB