top of page
FAC-3

Fully Anechoic 3m EMC Chamber

Overview

CISPR 16-1-4, IEC/EN 61000-4-22

 

IEC/EN 61000-4-3

​

3,0m

 

ø1,5 m at 1,5m height

 

Table top EUT’s

EMI

 

EMS

 

Test distance

 

Volume

 

Special

FAC-3 1.png

The FAC-3 is Frankonia’s fully anechoic chamber solution at 3,0m measuring distance for EMC tests on table top positioned EUT’s. It is designed as full compliant chamber for measurements under free-space conditions and is based on CISPR 16-1-4 as a test site without ground plane. Without the reflections from the floor, a height scan is no longer necessary. With its specific requirements for the test site, Frankonia’s FAC-3 is supremely prepared to meet our customers’ demands.

FAC-3 2.png

Features

>     Test site for table top EUT’s

>     Full compliant EMI/EMS

>     Cost effective solution for free-space measurements

>     Compact chamber design with advanced absorber lining with long-lasting Frankosorb® absorbers (Frankonia          

         technology)

>     Turnkey solution

Typical Product Standards

Emission

>     CISPR 14

>     CISPR 32

>     ETSI

Immunity

>     IEC/EN 61000-4-3

Typical Verification Standards

Emission

>     CISPR 16-1-4

>     IEC/EN 61000-4-22

Immunity

>     IEC/EN 61000-4-3

>     IEC/EN 61000-4-22

Technical specifications

Chamber

 

External dimension

 

EUT

 

Quiet Zone CISPR 16-1-4

 

Quiet Zone IEC/EN 61000-4-22

​

​

Measuring distance

 

Load capacity

 

Frequency range

FAC-3 

 

8.705 x 4.655 x 3.750 mm

 

Table-top EUT’s

 

ø1,5 m; height 1,5 m

 

ø1,5 m; height 1,5 m (30 MHz -1 GHz)
ø1,0 m; height 1,0 m (1 GHz -6 GHz)

​

3,0m

 

up to 2,0 tons; special turntable systems possible

 

30 MHz to 18 GHz (option 40 GHz)

Performance & Compliance

>     Full compliant emission (EMI) according to CISPR 16-1-4
        Deviation FS NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
        Deviation FS SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

>     Full compliant immunity (EMS) according to IEC/EN 61000-4-3
        Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed

>     Full compliant immunity (EMS) and emission (EMI) according to IEC/EN 61000-4-22 Standard
        Deviation SdB c ≤ 1,8 dB