Harmonics & Flicker

The Teseq ProfLine system is a complete and cost effective Harmonics and Flicker measurement test system which compiles to the latest IEC/EN standards, including IEC 61000-3-2 and IEC 61000-3-3. The programmable power generation capability of up to 45 kVA (90 kVA and 145 kVA sources comprise multiple 45 kVA units) provides more than ample power to cater for a wide range of Equipment Under Test (EUT).

 

In addition to harmonics and flicker testing capability, the AC/DC power source used in the system is capable of testing to a wide range of power quality immunity tests including:

 

Our detailed ProfLine brochure provides information about the system, the individual standards, and also a very detailed system selection chart which will help you select the exact configuration for your testing needs.

NSG 1007

Programmable AC and DC Power Sources

  • Combination AC and DC power source and power analyzer 

  • Arbitrary waveform generation

  • Built-in digital power analyzer

  • Meets source requirements for IEC 61000-3-2 and -3-3

  • 3 - 15 kVA for single and three phase applications (15 kVA per phase)

  • Description

Description

  • The NSG 1007 series sources are high efficiency, lightweight AC and DC power sources which include high performance power analyzers.

  • With a crest factor of up to 5:1, the NSG 1007 series sources can drive difficult nonlinear loads with ease. Since many modern products use switching power supplies, they have a tendency to draw high repetitive peak currents. The Teseq sources can deliver a repetitive peak current of up to three times their rated continuous current.

  • With precise output regulation and accuracy, the sources address many application areas for AC and DC power testing. They provide a high load current capability, multi or single phase output modes, and built-in power analyzer measurements. Additional features including line distortion simulation (LDS), arbitrary waveform generation, and programmable output impedance address requirements for product quality and regulatory compliance testing.

ProfLine 2100 - Measurement System 

Harmonics and Flicker Measuring System

  • Cost effective, complete and compliant

  • Variable output power configuration from 3 kVA to 45 kVA (90 and 145 kVA sources comprise multiple 45 kVA units)

  • Easily upgradeable PC based 

  • Use existing power sources or mains measurement system

  • Immunity test system

  • Key 'Equipment Under Test' electrical parameters updated continuously

  • User selectable test parameters and data display option

  • Test report customisation capability 

Description

System

  • ProfLine 2100 is an accurate and flexible system designed to measure harmonics & flicker in accordance with IEC 61000-3-2 and IEC 61000-3-3. This is a measuring system only and no AC source is supplied. It can therefore be used with any suitable, clean AC source to measure and record any harmonics & flicker created by the EUT. A wide range of AC sources are available from Teseq, please see ProfLine 2103, 2105, 2115, 2130, 2145 datasheets for suitable systems including power sources.

ProfLine 2103

3 kVA single Phase Harmonics & Flicker Measuring System

  • Low cost system for small DUTs

  • Complete test system including clean power source

  • Simulated flicker impedance, no need for expensive physical impedance

Description

System

  • ProfLine 2103 is an accurate and flexible single phase system designed to measure harmonics & flicker in accordance with IEC 61000-3-2 and IEC 61000-3-3, supporting testing on products consuming up to 11 Arms and 92 A peak @ 230 VAC. The system is supplied complete with a stable, accurate, programmable 3 kVA power source. The ProfLine 2103 system is therefore ready to measure and record any harmonics & flicker created by the EUT. A wide range of higher power AC source systems are available from Teseq, please see ProfLine 2105, 2115, 2130, 2145 datasheets for suitable systems at higher power or for three phase operation.

  • Measurements are made using precision, no burden, active hall-effect current transformers connected via a dedicated cable to a multichannel fast Data Acquisition Card (DAQ) fitted inside a PC. One voltage and three current measuring channels are used to make simultaneous measurement of both current and voltage. Calculations are made using dedicated Teseq software (WIN 2100) to determine harmonics (classes A-D), inter-harmonics, flicker, dc, dt, dmax, Pst, Plt, inrush current and 24 x dmax.

ProfLine 2105

5 kVA single Phase Harmonics & Flicker Measuring System

  • Complete test system for IEC 61000-3-2 and -3-3

  • Single phase system up to 16 A

  • Simulated flicker impedance, no need for expensive physical impedance

  • Power source suitable for testing to immunity standards

Description

System

  • ProfLine 2105 is an accurate and flexible single phase system designed to measure harmonics & flicker in accordance with IEC 61000-3-2 and IEC 61000-3-3. The system is supplied complete with a stable, accurate, programmable 5 kVA power source. The ProfLine 2105 system is therefore ready to measure and record any harmonics & flicker created by the EUT. A wide range of AC source systems are available from Teseq, please see ProfLine 2103, 2115, 2130, 2145 datasheets for suitable systems at different power levels or for three phase operation.

  • Measurements are made using precision, no burden, active hall-effect current transformers connected via a dedicated cable to a multichannel fast Data Acquisition Card (DAQ) fitted inside a PC. One voltage and three current measuring channels are used to make simultaneous measurement of both current and voltage. Calculations are made using dedicated Teseq software (WIN 2100) to determine harmonics (classes A-D), inter-harmonics, flicker, dc, dt, dmax, Pst, Plt, inrush current and 24 x dmax.

ProfLine 2115

15 kVA three Phase Harmonics & Flicker Measuring System

  • Complete test system for IEC 61000-3-2 and 3-3

  • Three phase system up to 16 A per phase

  • Power source suitable for testing to immunity standards

Description

System

  • ProfLine 2115 is an accurate and flexible three phase system designed to measure harmonics & flicker in accordance with IEC 61000-3-2 and IEC 61000-3-3. The system is supplied complete with a stable, accurate, programmable 5 kVA per phase power source. The ProfLine 2115 system is therefore ready to measure and record any harmonics and flicker created by the EUT. A wide range of different AC source systems are available from Teseq, please see ProfLine 2103, 2105, 2130, 2145 datasheets for suitable systems at other powers or for single phase operation. The system is delivered in a suitable 19” rack, fully integrated and ready to use with the supplied PC which has pre-installed software and calibration files.

  • Measurements are made using precision, no burden, active hall-effect current transformers connected via a dedicated cable to a multichannel fast Data Acquisition Card (DAQ) fitted inside a PC. One voltage and three current measuring channels per phase are used to make simultaneous measurement of both current and voltage. Calculations are made using dedicated Teseq software (WIN 2100) to determine harmonics (classes A-D), inter-harmonics, flicker, dc, dt, dmax, Pst, Plt, inrush current and 24 x dmax.

ProfLine 2130 

30 kVA three Phase Harmonics & Flicker Measuring System

  • Complete test system

  • IEC 61000-3-2, -3-3, -3-11 and -3-12

  • Three phase system up to 43 A per phase

  • Power source suitable for testing to many immunity standards

Description

System

  • ProfLine 2130 is an accurate and flexible three phase system designed to measure harmonics & flicker in accordance with IEC 61000-3-2 and IEC 61000-3-3. This system can also be used to test to IEC 61000-3-11 and IEC 61000-3-12 on products consuming up to 37 A per phase @ 230 VAC. The system is supplied complete with a stable, accurate, programmable 10 kVA per phase power source. The ProfLine 2130 system is therefore ready to measure and record any harmonics & flicker created by the EUT. A wide range of different AC source systems are available from Teseq, please see ProfLine 2103, 2105, 2115, 2145 datasheets for suitable systems at other powers or for single phase operation.

  • The system is delivered as a stand alone power supply unit and a suitable 19” rack housing the ancillary and measuring equipment, the system is ready to use with the supplied PC which has pre-installed software and calibration files.

ProfLine 2145

45 kVA three Phase Harmonics & Flicker Measuring System

  • Complete test system

  • IEC 61000-3-11 and -3-12

  • Option to include -3-2 and -3-3

  • Three phase system up to 62 A per phase

  • Power source suitable for testing to many immunity standards

Description

System

  • ProfLine 2145 is an accurate and flexible three phase system designed to measure harmonics & flicker in accordance with IEC 61000-3-12 and IEC 61000-3-11 on products consuming up to 62 A per phase @ 230 VAC. By adding the optional software and impedance this system can also be used to test to IEC 61000-3-2 and IEC 61000-3-3. The system is supplied complete with a stable, accurate, programmable 15 kVA per phase power source. The ProfLine 2145 system is therefore ready to measure and record any harmonics & flicker created by the EUT. A wide range of different AC source systems are available from Teseq, please see ProfLine 2103, 2105, 2115, 2130 datasheets for suitable systems at other powers or for single phase operation.

  • The system is delivered as a stand alone power supply unit and a suitable 19” rack housing the ancillary and measuring equipment, the system is ready to use with the supplied PC which has pre-installed software and calibration files.

Product Suggestions
Screen Shot 2556-06-02 at 3.41.37 PM.png

NSG 5071 
Inductive Switch Transient Test Circuit

  • Designed in accordance to Ford standard EMC-CS-2009

  • Transients disturbances CI 220 A and C pulses

  • CI 260 waveform F

  • User replaceable relays

Screen Shot 2556-06-02 at 3.42.42 PM.png

PA 5840
Power Amplifier/Battery Simulator

  • Large inrush current capability

  • Capacitive stability mode

  • High bandwidth up to 150 kHz

  • Fast slew rate

  • Two output ranges for power efficiency

Screen Shot 2556-06-02 at 4.40.25 PM.png

NSG 3040-EFT

  • Fully IEC 61000-4-4 compliant 

  • 16 A single phase CDN 

  • Large 7.2" color display and touch panel interface 

  • Standards and user test libraries 

  • Wide range of accessories 

Address