top of page
SAC-10 Plus

Semi Anechoic 10m EMC Chamber

Overview

EMI

 

EMS

 

Test distance

 

Volume

 

Special

CISPR 16-1-4 and ANSI C63.4

 

IEC/EN 61000-4-3

 

3,0m, 5,0m and 10,0m

 

ø3,0m

 

Compact 10m chamber

SAC-10 Plus 1.png

The SAC-10 Plus is Frankonia’s full compliant and state-of-the-art EMC testing solution at 10m, 5m & 3m measuring distances with a Quiet Zone (QZ) of ø3,0m. The innovative polygonal shape along with its optimized absorber layout is a space-saving, cost-saving and efficient solution with a single test axis. The SAC-10 Plus is fully compliant for emission tests validated according to CISPR 16-1-4, as well as full compliant for immunity tests according to IEC/EN 61000-4-3. In addition, the SAC-10 Plus is Frankonia’s most compact 10m chamber available to meet CISPR 16-1-4 and ANSI C63.4 test site requirements.

SAC-10 Plus 2.png

Features

>     10,0 m, 5,0 m & 3,0 m measuring distances with a Quiet Zone of ø3,0 m

>     Full compliant EMI/EMS

>     Ingenious absorber lining with Frankosorb®

>     Outstanding performance with long-lasting Frankosorb® non-combustible absorbers

>     Cost-saving and future-proof investment

>     Space-saving chamber in polygonal shape

>     Turnkey solution

Typical Product Standards

Emission

>     CISPR 11

>     CISPR 14

>     CISPR 15

>     CISPR 25

>     CISPR 32

>     MIL-STD 461

Immunity

>     IEC/EN 61000-4-3

>     ISO 11452

>     MIL-STD 461

Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.

Typical Verification Standards

Emission

>     CISPR 16-1-4 and/or          ANSI C63.4

Immunity

>     IEC/EN 61000-4-3

Technical specifications

External 

 

Version

 

Quiet Zone

 

Turntable

 

Measuring distance

 

Load capacity

 

Frequency range

19.205 x 12.080 x 8.325 mm

 

Polygonal shape design with single test axis

 

ø3,0 m

 

ø3,0 m or ø4,0 m

 

10,0 m, 5,0 m and 3,0 m

 

up to 5,0 tons; special turntable systems possible

 

30 MHz to 18 GHz (option 40 GHz)

Performance & Compliance

>     Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4
        Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
        Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

>     Full compliant immunity (EMS) according to IEC/EN 61000-4-3
        Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed

bottom of page