SAC-3 / FAC-3 Transformer
Semi and Fully Anechoic 3m EMC Chamber Combination
Overview
EMI
EMS
Test distance
Volume
Special
CISPR 16-1-4, ANSI C63.4 and IEC/EN 61000-4-22
IEC/EN 61000-4-3
3,0m
ø2,0 m as SAC Chamber
ø1,5 m as FAC Chamber
Transformable test site from SAC to FAC
The SAC-3/FAC-3 Transformer is Frankonia’s full compliant EMC testing solution at 3,0m measuring distance offering semi as well as fully conditions. The SAC configuration provides a Quiet Zone (QZ) of ø2,0m and is compliant with CISPR 16-1-4 as well as ANSI C63.4. The FAC configuration provides a Quiet Zone (QZ) of ø1,5m and is compliant with CISPR 16-1-4 as well as IEC/EN 61000-4-22. The SAC-3/FAC-3 Transformer chamber is adapted for full compliant emissions and immunity testing with a traditional “square design”.
Features
> Transformable from SAC to FAC test site
> Cost-effective solution combining an SAC with an FAC chamber
> High-performance for a 3,0 m measuring distance
> Full compliant EMI/EMS
> Adapted steel structure and optimized RF-shielding with traditional rectangular design
> Ingenious absorber lining with Frankosorb®
> Outstanding performance with long-lasting Frankosorb® non-combustible absorbers
> Turnkey solution
Typical Product Standards
Emission
> CISPR 11
> CISPR 14
> CISPR 15
> CISPR 25
> CISPR 32
> MIL-STD 461
> ETSI
Immunity
> IEC/EN 61000-4-3
> ISO 11452
> MIL-STD 461
Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.
Typical Verification Standards
Emission
> CISPR 16-1-4 and/or ANSI C63.4
> IEC/EN 61000-4-22
Immunity
> IEC/EN 61000-4-3
> IEC/EN 61000-4-22
Technical specifications
Chamber Type
External dimension
Version
Quiet Zone
Quiet Zone IEC/EN 61000-4-22
​
​
Measuring distance
Load capacity
Frequency range
SAC-3 / FAC-3 Transformers
9.680 x 6.530 x 6.000 mm
Square design
ø2,0 m; height 1,5 m (SAC)
ø1,5 m; height 1,5 m (FAC)
ø1,5 m; height 1,5 m (30 MHz -1 GHz)
ø1,0 m; height 1,0 m (1 GHz -6 GHz)
​
3,0m
up to 5,0 tons; special turntable systems possible
30 MHz to 18 GHz (option 40 GHz)
Performance & Compliance – Semi Configuration
> Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4
Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed
> Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed
Performance & Compliance – Fully Configuration
> Full compliant emission (EMI) according to CISPR 16-1-4
Deviation FS NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation FS SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed
> Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed
> Full compliant immunity (EMS) and emission (EMI) according to IEC/EN 61000-4-22 Standard
Deviation SdB c ≤ 1,8 dB