Overview

EMI

 

 

EMS

 

Test distance

 

Volume

 

 

Special

CISPR 16-1-4, ANSI C63.4 and IEC/EN 61000-4-22

 

IEC/EN 61000-4-3

 

3,0m

 

ø2,0 m as SAC Chamber
ø1,5 m as FAC Chamber

 

Transformable test site from SAC to FAC

SAC-3_FAC-3 Transformer 1.png

The SAC-3/FAC-3 Transformer is Frankonia’s full compliant EMC testing solution at 3,0m measuring distance offering semi as well as fully conditions. The SAC configuration provides a Quiet Zone (QZ) of ø2,0m and is compliant with CISPR 16-1-4 as well as ANSI C63.4. The FAC configuration provides a Quiet Zone (QZ) of ø1,5m and is compliant with CISPR 16-1-4 as well as IEC/EN 61000-4-22. The SAC-3/FAC-3 Transformer chamber is adapted for full compliant emissions and immunity testing with a traditional “square design”.

SAC-3_FAC-3 Transformer 2.png

Features

>     Transformable from SAC to FAC test site

>     Cost-effective solution combining an SAC with an FAC chamber

>     High-performance for a 3,0 m measuring distance

>     Full compliant EMI/EMS

>     Adapted steel structure and optimized RF-shielding with traditional rectangular design

>     Ingenious absorber lining with Frankosorb®

>     Outstanding performance with long-lasting Frankosorb® non-combustible absorbers

>     Turnkey solution

Typical Product Standards

Emission

>     CISPR 11

>     CISPR 14

>     CISPR 15

>     CISPR 25

>     CISPR 32

>     MIL-STD 461

>     ETSI

Immunity

>     IEC/EN 61000-4-3

>     ISO 11452

>     MIL-STD 461

Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.

Typical Verification Standards

Emission

>     CISPR 16-1-4 and/or           ANSI C63.4

>     IEC/EN 61000-4-22

Immunity

>     IEC/EN 61000-4-3

>     IEC/EN 61000-4-22

Technical specifications

Chamber Type

 

External dimension

 

Version

 

Quiet Zone

 

 

Quiet Zone IEC/EN 61000-4-22

​

​

Measuring distance

 

Load capacity

 

Frequency range

SAC-3 / FAC-3 Transformers 

 

9.680 x 6.530 x 6.000 mm

 

Square design

 

ø2,0 m; height 1,5 m (SAC)
ø1,5 m; height 1,5 m (FAC)

 

ø1,5 m; height 1,5 m (30 MHz -1 GHz)
ø1,0 m; height 1,0 m (1 GHz -6 GHz)

​

3,0m

 

up to 5,0 tons; special turntable systems possible

 

30 MHz to 18 GHz (option 40 GHz)

Performance & Compliance  – Semi Configuration

>     Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4

        Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed

        Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

>     Full compliant immunity (EMS) according to IEC/EN 61000-4-3

        Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed

Performance & Compliance  – Fully Configuration

>     Full compliant emission (EMI) according to CISPR 16-1-4

        Deviation FS NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed

        Deviation FS SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

>     Full compliant immunity (EMS) according to IEC/EN 61000-4-3
        Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed

>     Full compliant immunity (EMS) and emission (EMI) according to IEC/EN 61000-4-22 Standard
        Deviation SdB c ≤ 1,8 dB