ACTC
Automotive Component Testing Chamber
Overview
EMI
EMS
Test distance
Volume
CISPR 25 Ed.4
ISO 11452
1,0 m
Table setup
The ACTC is Frankonia’s automotive component testing chamber solution at 1,0m measuring distance. This chamber solution is adapted for full compliant tests of automotive components according to CISPR 25 and ISO 11452. A permanent plug-in contact strip is installed between the absorbers to ensure the electrical connection of the test table to the shielding, and includes the test table as required per to CISPR 25. The typical chamber is lined with ferrite absorbers and partially lined with Frankosorb® hybrid absorbers.
Features
> Compact chamber solution for automotive component testing according to CISPR 25
> Full compliant EMI/EMS
> Upgradeable for E-Drive (load machine, BlueBox, battery test system)
> Advanced absorber lining with long-lasting Frankosorb® absorbers (Frankonia technology)
> Turnkey solution
Typical Verification Standards
Emission
> CISPR 25 Ed-4 (ALSE, long-wire method)
Immunity
> ISO 11452
Technical specifications
Chamber
External dimension
​
Setup
Measuring distance
​
Frequency range
ACTC
6.380 x 5.480 x 3.750 mm
Table setup
1,0 m
150 kHz to 18 GHz (option 40 GHz)
ACTC L
11.480 x 6.580 x 4.500 mm
Table and vehicle setup
Performance & Compliance
> Full compliant emission (EMI) according to CISPR 25 Ed.4
(ALSE verification acc.to the long-wire method recommended)
> Full compliant immunity (EMS) according to ISO 11452