AVTC
Automotive Component and Vehicle Testing Chamber
Overview
CISPR 16-1-4 and ANSI C63.4
CISPR 12 and CISPR 25
IEC/EN 61000-4-3
ISO 11451 and ISO 11452
3,0m or 5,0m
Ø3,0m
Combination for commercial and automotive tests
EMI
EMS
Test distance
Volume
Special
The AVTC chambers are Frankonia’s automotive anechoic chamber solution at 3,0m or 5,0m measuring distance offering a Quiet Zone (QZ) of ø3,0 m up to ø6,0 m for commercial testing combined with a focus to automotive tests. It is adapted for radiated emissions on vehicles acc.to CISPR 12 and components acc.to CISPR 25 as well as for commercial product tests acc.to CISPR 16-1-4 and ANSI C63.4. Furthermore, it is adapted to radiated immunity acc.to IEC/EN 61000-4-3, ISO 11451 and ISO 11452.
Features
> Automotive component and vehicle tests together with commercial tests in a single solution
> Cost-effective and high-performance solution for a 3,0 m or 5,0 m measuring distance
> Floor-absorberboard for an efficient and fast modification of the test setup
> Upgradeable with EDTC components (load machine, BlueBox, battery test system)
> Turnkey solution
Typical Product Standards
Emission
> CISPR 11
> CISPR 12
> CISPR 14
> CISPR 15
> CISPR 25
> CISPR 32
> CISPR 36 (draft)
> MIL-STD 461
Immunity
> IEC/EN 61000-4-3
> ISO 11451
> ISO 11452
> MIL-STD 461
Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.
Typical Verification Standards
Emission
> CISPR 16-1-4 and/or ANSI C63.4
> CISPR 25 Ed-4 (ALSE, long-wire method)
Immunity
> IEC/EN 61000-4-3
> ISO 11452
Technical specifications
Chamber Type
External dimension
​
Quiet Zone
Measuring distance
Turntable
Load capacity
​
Frequency range
AVTC
11.480 x 9.380 x 6.000 mm
ø3,0 m
3,0 m
​
ø5,0 m
AVTC L
​
14.780 x 11.480 x 6.300 mm
​
ø3,0 m
3,0 m & 5,0 m
​
Ø6,0 m
AVTC XL
​
16.280 x 12.680 x 6.300 mm
​
ø6,0 m
3,0 m
​
Ø7,8 m (dyno)
up to 20,0 tons; special turntable systems and dynamometer integration possible
150 kHz to 18 GHz (option 40 GHz)
Performance & Compliance
> Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4
Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed
> Full compliant emission (EMI) according to CISPR 25 Ed.4
(ALSE verification acc.to the long-wire method recommended)
> Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed
> Full compliant immunity (EMS) according to ISO 11452