MIL-CHC / DO-160
MIL-STD / DO-160
MIL-STD / DO-160
1,0 m
Table setup
EMI
EMS
Test distance
Volume
Overview
Military Components Testing Chamber
The MIL CHC is Frankonia’s compact hybrid chamber solution according to MIL-STD 461 and DO-160 for component tests. This chamber solution is adapted for radiated emission and immunity tests at 1,0 m measuring distance.
Features
> Turnkey solution Compact chamber design for military applications
> MIL-STD 461, or in combination with DO-160
> Advanced absorber lining with long-lasting Frankosorb® absorbers (Frankonia technology)
> Full compliant EMI/EMS
> Turnkey solution
Typical Product Standards
Emission
> MIL-STD 461
> DO-160
Immunity
> MIL-STD 461
> DO-160
Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.
Technical specifications
Chamber
External dimension
​
Measuring distance
​
Frequency range
MIL-CHC
4.880 x 4.880 x 3.000 mm
1,0 m
30/80 MHz to 18 GHz (option 40 GHz)
MIL-CHC / DO-160
5.330 x 4.880 x 3.000 mm
Performance & Compliance
> Full compliant emission (EMI) according to MIL-STD 461 and DO-160
> Full compliant immunity (EMS) according to MIL-STD 461 and DO-160
> Absorption at normal incidence:
80 MHz to 250 MHz ≥ 6 dB, as per standard requirements
above 250 MHz ≥ 10 dB, as per standard requirements