MIL-STD Chamber Advanced
Military Testing Chamber for Vehicles, large EUT’s, and Commercial Tests
Overview
MIL-STD / DO-160
MIL-STD / DO-160
1,0 m
No test volume
CISPR 16-1-4 and ANSI C63.4
​
IEC/EN 61000-4-3
​
​
Adapted to any EUT type and size
EMI
EMS
Test distance
Volume
EMI Advanced
​
EMS Advanced
​
Special
The MIL STD Chamber Advanced are Frankonia’s military chamber solutions according to MIL-STD 461 for large EUT’s. It is adapted for radiated emission and immunity tests at 1,0m measuring distance. This chamber solution is designed based on MIL-STD 461 and is fully customized according to customers’ requirements for military testing of heavyweight and large EUT’s.
Frankonia’s unique Frankosorb® long-pyramid or hybrid absorber technology offers the possibility to combine MIL-STD 461 test requirements with commercial test requirements per CISPR 16-1-4 and ANSI C63.4, as well as a vehicle and automotive component tests.
Features
> High performance solution for military testing
> Various testing possibilities in the combination of commercial, automotive and military
> Advanced absorber lining with long-lasting Frankosorb® absorbers (Frankonia technology)
> Full compliant EMI/EMS
> Highly customizable solution for any kind of EMC testing and limitless integration of individual applications
> Adjustable chamber size, characteristics and configuration due to different EUT requirements
> Turnkey solution
Typical Product Standards
Emission
> CISPR 11
> CISPR 12
> CISPR 14
> CISPR 15
> CISPR 25
> CISPR 32
> MIL-STD 461
Immunity
> IEC/EN 61000-4-3
> ISO 11451
> ISO 11452
> MIL-STD 461
Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.
Typical Verification Standards
Emission
> CISPR 16-1-4 and/or ANSI C63.4
Immunity
> IEC/EN 61000-4-3
Technical specifications
Chamber
External dimension
​
Measuring distance
​
Load capacity
​
Frequency range
MIL-STD Chamber
To be defined
1,0 m
up to 80 tons; special turntable systems and integrations possible
26/80 MHz to 18 GHz (option 40 GHz)
Performance & Compliance
> Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4
Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed
> Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed
> Full compliant emission (EMI) according to MIL-STD 461 and DO-160
> Full compliant immunity (EMS) according to MIL-STD 461 and DO-160
> Absorption at normal incidence:
80 MHz to 250 MHz ≥ 6 dB, as per standard requirements
above 250 MHz ≥ 10 dB, as per standard requirements