top of page
SAC-10/H Hybrid

Semi Anechoic 10m EMC Chamber with Hybrid Absorbers

Overview

CISPR 16-1-4 and ANSI C63.4

 

IEC/EN 61000-4-3

 

up to 10,0 m

 

ø3,0 m up to ø6,0 m

 

Customized hybrid absorber lining

EMI

 

EMS

 

Test distance

 

Volume

 

Special

SAC-10_H Hybrid 1.png

The SAC-10/H are Frankonia’s full compliant and customizable EMC testing solutions at 10,0m measuring distance with a Quiet Zone (QZ) of ø3,0m up to ø6,0m with hybrid absorber layout. Due to the high grade of customization reflecting the demands of our customers, this semi-anechoic chamber is adaptable in size and offers several configuration possibilities. The innovative concept with its impressionable absorber layout achieves exceptional performance for emissions and immunity testing.

SAC-10_H Hybrid 2.png

Features

>     Frankosorb® Hybrid Absorber Lining

>     Highly customizable solution for any kind of EMC testing and limitless integration of individual applications

>     Adjustable chamber size, characteristics and configuration due to different EUT requirements

>     Advanced absorber lining with long-lasting Frankosorb® absorbers (Frankonia technology)

>     Specialized for ‘out-of-the-range’ EMC test environments

>     Turnkey solution

Typical Product Standards

Emission

>     CISPR 11

>     CISPR 12

>     CISPR 14

>     CISPR 15

>     CISPR 25

>     CISPR 32

>     MIL-STD 461

Immunity

>     IEC/EN 61000-4-3

>     ISO 11451

>     ISO 11452

>     MIL-STD 461

Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.

Typical Verification Standards

Emission

>     CISPR 16-1-4 and/or          ANSI C63.4

Immunity

>     IEC/EN 61000-4-3

Technical specifications

Chamber Type

 

External dimension

 

Quiet Zone at 3,0m

 

Quiet Zone at 5,0m

 

Quiet Zone at 10,0m

 

Load capacity

 

Frequency range

SAC-10-3/P

 

18.380 x 12.830 x 8.550 mm

 

ø3,0 m

 

ø3,0 m

ø3,0 m

SAC-10-4/P

19.280 x 13.280 x 8.550 mm

ø3,0 m

 

ø4,0 m

ø4,0 m

SAC-10-5/P

21.080 x 15.080 x 8.550 mm

ø3,0 m

 

ø5,0 m

ø5,0 m

SAC-10-6/P

 

21.680 x 15.680 x 8.700 mm

 

ø3,0 m

 

ø5,0 m

ø6,0 m

up to 80,0 tons; special turntable systems and dynamometer integration possible

 

30 MHz to 18 GHz (option 40 GHz)

Performance & Compliance

>     Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4

        Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed

        Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

>     Full compliant immunity (EMS) according to IEC/EN 61000-4-3

Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed

bottom of page