SAC-10/P Pyramid
Semi Anechoic 10m EMC Chamber with Long-pyramid P2400 Absorbers
Overview
EMI
EMS
Test distance
Volume
Special
CISPR 16-1-4 and ANSI C63.4
IEC/EN 61000-4-3
up to 10,0 m
ø3,0 m up to ø6,0 m
Long-pyramid absorber lining
The SAC-10/P are Frankonia’s full compliant and customizable EMC testing solutions at 10,0m measuring distance with a Quiet Zone (QZ) of ø3,0m up to ø6,0m and Frankonia’s unique long-pyramid absorber layout. Due to the high grade of customization reflecting the demands of our customers, this semi-anechoic chamber is adaptable in size and offers several configuration possibilities. The innovative concept with its impressionable absorber layout achieves exceptional performance for emissions and immunity testing.
Features
> Frankosorb® Long-pyramid Absorber Lining
> Highly customizable solution for any kind of EMC testing and limitless integration of individual applications
> Adjustable chamber size, characteristics and configuration due to different EUT requirements
> Advanced absorber lining with long-lasting Frankosorb® absorbers (Frankonia technology)
> Specialized for ‘out-of-the-range’ EMC test environments
> Turnkey solution
Typical Product Standards
Emission
> CISPR 11
> CISPR 12
> CISPR 14
> CISPR 15
> CISPR 25
> CISPR 32
> MIL-STD 461
Immunity
> IEC/EN 61000-4-3
> ISO 11451
> ISO 11452
> MIL-STD 461
Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.
Typical Verification Standards
Emission
> CISPR 16-1-4 and/or ANSI C63.4
Immunity
> IEC/EN 61000-4-3
Technical specifications
Chamber Type
External dimension
​
Quiet Zone at 3,0m
Quiet Zone at 5,0m
Quiet Zone at 10,0m
Load capacity
​
Frequency range
SAC-10-3/P
21.680 x 13.730 x 8.550 mm
ø3,0 m
ø3,0 m
​
ø3,0 m
SAC-10-4/P
​
21.680 x 13.730 x
8.550 mm
​
ø3,0 m
ø4,0 m
​
ø4,0 m
SAC-10-5/P
​
23.480 x 16.580 x 9.000 mm
​
ø3,0 m
ø5,0 m
​
ø5,0 m
SAC-10-6/P
24.980 x 17.180 x 9.000 mm
ø3,0 m
ø5,0 m
​
ø6,0 m
up to 80,0 tons; special turntable systems and dynamometer integration possible
26 MHz to 18 GHz (option 40 GHz)
Performance & Compliance
> Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4
Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed
> Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed