top of page

Semi Anechoic 10m EMC Chamber with Multi-axes

Overview

CISPR 16-1-4 and ANSI C63.4

 

IEC/EN 61000-4-3

 

3,0m, 5,0m and 10,0m

 

ø3,0m

 

Compact 10m chamber

EMI

 

EMS

 

Test distance

 

Volume

 

Special

SAC-10 Plus Triton 1.png
SAC-10 Plus Triton 2.png
SAC-10 Plus Triton

The SAC-10 Plus Triton is Frankonia’s full compliant and state-of-the-art EMC testing solution with multiple test axes at 10m, 5m & 3m measuring distances with a Quiet Zone (QZ) of ø3,0m. The innovative polygonal shape along with its optimized absorber layout allows for a usage of multiple axes having a ready test setup for emission and immunity tests. The benefits of its multiple test axes allow our customers to measure all required EMI/EMS procedures without the need to modify the test environment or the test setup. The test equipment and instruments can remain connected in the chamber. The absorber areas necessary for each test can be provided with guided movement. Due to the reproducible test setup, the SAC-10 Plus offers outstanding performance for NSA, SVSWR and FU and real time savings.

Features

>     Multiple test axis

>     is 10,0 m, 5,0 m & 3,0 m measuring distances with a Quiet Zone of ø3,0 m

>     Full compliant EMI/EMS

>     No need to modify the test environment or the test setup

>     Floor absorbers remain in the chamber with guided movements (manual or semi- automatic)

>     Antennas remain in the chamber

>     Quality of testing at a constant high level

>     Test time decreases considerably

>     Excellent performance in a compact chamber size

>     Ingenious absorber lining with Frankosorb®

>     Cost-saving and future-proof investment

>     Space-saving chamber in polygonal shape

>     Easy and efficient to use

>     Malfunctions or damages are almost impossible

>     Optimized workflow

>     Turnkey solution

Typical Product Standards

Emission

>     CISPR 11

>     CISPR 14

>     CISPR 15

>     CISPR 25

>     CISPR 32

>     MIL-STD 461

Immunity

>     IEC/EN 61000-4-3

>     ISO 11452

>     MIL-STD 461

Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.

Typical Verification Standards

Emission

>     CISPR 16-1-4 and/or          ANSI C63.4

Immunity

>     IEC/EN 61000-4-3

Technical specifications

External dimension

 

Version

 

Quiet Zone

 

Turntable

 

Measuring distance

 

 

 

Load capacity

 

Frequency range

19.205 x 12.080 x 8.325 mm

 

Polygonal shape design with multiple test axes

 

ø3,0 m

 

ø3,0 m or ø4,0 m

 

Test axis 1: 10,0 m, 5,0 m and 3,0 m
Test axis 2: 3,0 m
Test axis 3: 3,0 m

 

up to 5,0 tons; special turntable systems possible

 

30 MHz to 18 GHz (option 40 GHz)

Performance & Compliance

>     Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4
        Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
        Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

>     Full compliant immunity (EMS) according to IEC/EN 61000-4-3
        Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed